Basic network troubleshooting.

Basic network troubleshooting.
Basic network troubleshooting.

Cause...

If a computer is unable to connect to a network or see other computers on a network, it may be necessary to troubleshoot the network. A network may not work because of any of the below reasons.
Network card not connected properly.
Bad network card drivers or software settings.
Firewall preventing computers from seeing each other.
Connection related issues.
Bad network hardware.

Solution:

Because of the large variety of network configurations, operating systems, setup, etc... not all of the below information may apply to your network or operating system. If your computer is connected to a company or large network, or you are not the administrator of the network, it is recommended that if you are unable to resolve your issues after following the below recommendations that you contact the network administrator or company representative.

Note: If you are being prompted for a Network password and do not know the password, Computer Hope is unable to assist users with obtaining a new or finding out the old password.

Verify connections / LEDs

Verify that the network cable is properly connected to the back of the computer. In addition, when checking the connection of the network cable, ensure that the LEDs on the network are properly illuminated. For example, a network card with a solid green LED or light usually indicates that the card is either connected or receiving a signal. Note: generally, when the green light is flashing, this is an indication of data being sent or received.

If, however, the card does not have any lights or has orange or red lights, it is possible that either the card is bad, the card is not connected properly, or that the card is not receiving a signal from the network.

If you are on a small or local network and have the capability of checking a hub or switch, verify that the cables are properly connected and that the hub or switch has power.

Adapter resources

Ensure that if this is a new network card being installed into the computer that the card's resources are properly set and/or are not conflicting with any hardware in the computer.

Users who are using Windows 95, 98, ME, 2000 or XP, verify that Device Manager has no conflicts or errors. Additional help and information about Device Manager and resources can be found on our Device Manager page.

Adapter functionality


Verify that the network card is capable of pinging or seeing itself by using the ping command. Windows / MS-DOS users ping the computer from a MS-DOS prompt. Unix / Linux variant users ping the computer from the shell.

To ping the card or the localhost, type either

ping 127.0.0.1

or

ping localhost

This should show a listing of replies from the network card. If you receive an error or if the transmission failed, it is likely that either the network card is not physically installed into the computer correctly, or that the card is bad.

Protocol

Verify that the correct protocols are installed on the computer. Most networks today will utilize TCP/IP, but may also utilize or require IPX/SPX and NetBEUI.

Additional information and help with installing and reinstalling a network protocol can be found on document CH000470.

When the TCP/IP protocol is installed, unless a DNS server or other computer assigns the IPX address, the user must specify an IP address as well as a Subnet Mask. To do this, follow the below instructions.

Click Start / Settings / Control Panel

Double-click the Network icon

Within the configuration tab double-click the TCP/IP protocol icon. Note: Do not click on the PPP or Dial-Up adapter, click on the network card adapter.

In the TCP/IP properties click the IP address tab

Select the option to specify an IP address

Enter the IP address and Subnet Mask address, an example of such an address could be:

IP Address: 102.55.92.1
Subnet Mask: 255.255.255.192


When specifying these values, the computers on the network must all have the same Subnet Mask and have a different IP Address. For example, when using the above values on one computer you would want to use an IP address of 102.55.92.2 on another computer and then specify the same Subnet Mask.

Firewall

If your computer network utilizes a firewall, ensure that all ports required are open. If possible, close the firewall software program or disconnect the computer from the firewall to ensure it is not causing the problem.

Additional time

In some cases it may take a computer some additional time to detect or see the network. If after booting the computer you are unable to see the network, give the computer 2-3 minutes to detect the network. Windows users may also want to try pressing the F5 (refresh) key when in Network Neighborhood to refresh the network connections and possibly detect the network.

Additional troubleshooting

If after following or verifying the above recommendations you are still unable to connect or see the network, attempt one or more of the below recommendations.

If you have installed or are using TCP/IP as your protocol you can attempt to ping another computer's IP address to verify if the computer is able to send and receive data. To do this, Windows or MS-DOS users must be at a prompt and Linux / Unix variant users must open or be at a shell.

Once at the prompt assuming, that the address of the computer you wish to attempt to ping is 102.55.92.2, you would type:

ping 102.55.92.2

If you receive a response back from this address (and it is a different computer), this demonstrates that the computer is communicating over the network. If you are still unable to connect or see the network, it is possible that other issues may be present.

Another method of determining network issues is to use the tracert command if you are a MS-DOS or Windows user or the traceroute command if you are a Linux / Unix variant user. To use this command you must be at the command prompt or shell.

Once at the prompt, assuming that the address is again 102.55.92.2, type:

tracert 102.55.92.2

or

traceroute 102.55.92.2

This should begin listing the hops between the computer and network devices. When the connection fails, determine which device is causing the issue by reviewing the traceroute listing.

(source : http://www.computerhope.com)

PC Mainboard Identification

PC Mainboard Identification
Every now and then, we see questions in the PC911 Forum regarding identification of the mainboard installed in a PC

Many users simply don't know the make and model of the mainboard (motherboard or mobo) that their systems are built around. Does this really matter? No ... not unless and until something goes wrong where you need that info to effect a repair. Or, until you decide to perform some DIY system upgrade and suddenly you need to know something specific about the board.

If all was done according to Hoyle when you purchased your system, you received some sort of documentation with it. Many times, that documentation will include at least a spec sheet itemizing the individual components, and at best it will include a User's Guide or manual for the mobo.


Several types of system upgrades might require the user to have this documentation. Sometimes, you will need to change jumper or DIP switch settings when installing a processor of a different type or speed. Some memory changes will also require such changes. Then there are such tasks as enabling or disabling integrated sound, modem, and video features. Or, maybe you're just plain curious! If you find yourself in the position of needing to identify an unknown mainboard, fret not - there are several workable alternatives to throwing darts at a list of mobo makers.

In this article, I will concentrate on the American Megatrends and Award BIOS'es, as they are by far the ones most commonly used by modern desktop systems. I will address three basic methods for use in determining your mainboard manufacturer.

The "Lookatit" Method...

The first thing to do, and probably the last thing that many folks think of, is to simply "look at it". Many mobo makers will screen-print their ID right on the board. Ideally this ID will be on the upper (visible) surface of the board, but this is often not the case with "generic" mobo's. With some of these boards, if they are ID'ed at all, it is on the lower surface, which is normally not visible on an installed board.

Look carefully at the entire surface of the board, including those areas that may be hidden behind drives, cables, or the power supply. Many boards are labeled between their expansion slots. Another common location on newer boards is in the area of the CPU slot or socket. Also, be aware that while the board may not have its maker's name showing, it just may have its model name or number printed there for all the world to see.

While you are searching the board for make and model info, take a minute to note the location of any jumpers or DIP switches on the board. If you are doing an upgrade requiring resetting any of these devices, it will help to know where they are located. Figures 1A through 1E illustrate the mainboard identification schemes used on four different mainboards.


Figure 1A - Two model numbers on same board, on side of ISA slot



Making a Low-cost LAN Cable Tester

Making a Low-cost LAN Cable Tester
One of the more popular experiments that users with multiple PC's will try is the installation of a home network or LAN

LAN is geekspeak for Local Area Network - the correct term applied to any network installed in a limited physical area. In the not-too-distant past, it was common practice to install home LAN's using coaxial cable, as it was simple to install, readily available prefabricated in standard lengths, and it required no additional components besides the Network Interface Card (NIC) and some hardware - tees and terminators. The alternative was to use unshielded twisted pair (UTP) cable, usually called 10Base-T cable. This cable resembles standard telephone cable found in most homes today, except that it is heavier, having four pairs of wires instead of two pairs. Because of the additional four wires, the modular plug used with 10Base-T is an eight-conductor device, which is known as an RJ-45 connector.

Using 10Base-T with more than two PC's requires the installation of an additional connectivity device. This device can be a hub, a switch, or a router, depending upon the particular requirements of the LAN. All of this means that the user will be installing multiple connecting cables of varying lengths, and possibly of varying circuit schemes. In general, there will be one cable connecting each PC to the hub. Additional cables may be used to daisy-chain multiple hubs together, or to connect the hub to a broadband modem, or to connect a second NIC in certain PC's to another LAN. 10Base-T cables are also available prefabricated in standard lengths.



The choice between using prefabricated cables and "rolling your own" in a matter of personal preference. Some users will choose to simply purchase prefabricated cables, plug them in, and hopefully have an operable LAN. Others will decide to assemble the LAN cables as they are needed, which provides the option of having cables that are exactly the right length. An added benefit is found when actually pulling the cables into place, as the cable sans connector will not require large holes to be drilled in walls, ceilings, or floors. Depending upon the number of cables required, overall costs may well even out, as the cost savings realized with bulk cable will be reduced by the cost of the necessary cable assembly tools. Radio Shack offers an RJ45 crimper for around $30.00 (p/n 279-405), a BNC (coax) crimper for around $16.00 (p/n 278-238), and a coax stripper for about $12.00 (p/n 278-248). The UTP jacket stripper is usually built into the crimper tool assembly. Of course, prices for the necessary tools will vary based upon supplier and area. I mention the Radio Shack items only because they are available in retail stores across the country, and this gives the reader a basis for comparison both in terms of price and tool design.

OK - I said earlier "...hopefully have an operable LAN". By now, you are probably wondering what I meant by that remark, right? Well, what happens when the LAN doesn't perform as expected - or maybe doesn't even seem to connect at all? Obviously the time is at hand for some basic LAN troubleshooting... and troubleshooting will sometimes require test equipment.

The purpose of this article is to help you create a simple but reliable 10Base-T cable tester that will work with any continuity tester or ohmmeter.

A Word on Ohmmeters

It is my humble opinion that a decent multimeter be a permanent resident in the toolkit of anyone who is going to be doing any kind PC testing and repair. There are many good meters available at very reasonable prices today. In keeping with the Radio Shack product suggestions, I would recommend their model 22-163 as an excellent general-purpose multimeter for around $50.00. Those who are looking for more bells and whistles should consider model 22-805, which offers a PC interface and sells for about $60.00, or model 22-174, which offers temperature sensing, a frequency counter, and true RMS read-out for about $90.00. For what it's worth, the $50.00 model is in my service call toolkit. Make sure that whatever multimeter you use is of at least that quality, as a poorly designed or built multimeter will provide erroneous readings to the user. There's no real need to go into the theory behind this - just accept my word on this, as it is fact.

A Word on Cable Types and Nomenclature

There are a few somewhat ambiguous terms that are frequently heard when discussing network cables. These include CAT 3, CAT 5 , 10Base-T, and 100Base-T. In order to take some of the confusion out, let's take a quick look at what these terms mean.

I have already used the term 10Base-T. This term is used to indicate the character of the LAN, with the "10" referring to the maximum transmission speed of 10Mbps. The "Base" portion of the designation refers to "baseband signalling", and is used to indicate that the medium is carrying Ethernet signals only. The "T" suffix indicates that the transmission medium is a twisted-pair wire.

The term 100Base-T is a similar term. In this case however, the "100" indicates a maximum transmission speed of 100Mbps, and the "T" suffix will sometimes be seen with an additional digit tagged on. The additional digit is used to further describe the medium type, with a "4" indicating telephone-grade twisted pair wire, and an "X" indicating data-grade twisted pair wire.

The twisted pair wire and associated connectors and junctions used in the transmission of network signals are rated as regards the maximum data rates that they can "sustain", or carry continually. The American National Standards Institute/Electronic Industries Association (ANSI/EIA) Standard 568 specifies "categories" of these devices, based upon their performance capability. A component that is labeled as a CAT 3 component is one that meets the Category 3 minimum performance requirements. The pertinent categories for Ethernet cabling are CAT 3 and CAT 5. CAT 3 components must be able to sustain a data rate of 16 Mbps, while CAT 5 components must be able to sustain a data rate of 100Mbps. In order for a fabricated cable to meet the CAT 3 standard, it must be performance tested (after assembly) at a data rate of 16Mbps. Similarly, in order for a fabricated cable to meet the CAT 5 standard, it must be performance tested (after assembly) at a data rate of 100Mbps.

Category 5 cable can always be used in a 10Base-T LAN, as it far exceeds the data rate capability involved there. On the other hand, the fact that CAT 5 rated cable, connectors, and patch panels are used does not automatically mean that an installation will be 100Base-T capable, and I have seen numerous 100Base-T LAN's operating over cables assembled from CAT 3 rated bulk cable.

The primary difference between the two isn't the cable itself, and the CAT 5 designation as applied to the bulk cable can be misleading to the uninformed. CAT 5 approved cable assembled to CAT 5 approved connectors may not even meet CAT 3 near-end crosstalk (NEXT) minimums if poorly assembled, whereas CAT 3 approved cable, when properly assembled to high-quality connectors can and often will perform at CAT 5 levels. Many homemade "CAT 5" cables, when tested for performance certification, will fail the testing. These cables will therefore not perform at CAT 5 levels at all. The fact that a cable assembly is constructed using CAT 5 materials doesn't make it a CAT 5 (100Base-T) cable... the only thing that makes it a 100Base-T cable is passing the required performance tests at that level.

The tester described in this article is a basic continuity tester rather than a performance level test device. It is intended for use as a troubleshooting tool for basic connectivity testing rather than for performance issue resolution. However, it will work as a basic continuity tester for any standard UTP/RJ45 cable as used in an Ethernet installation. This applies to cable assemblies made with both CAT 3 and CAT 5 bulk cable.

A Word on Cable Fabrication

It is not the intent of this article to go into any detail on the steps involved in the fabrication of LAN cables. There are several references available to the user on that topic, including a PC911 How-To that explains the process of assembling 10Base-T cables. Rather, I will deal with the steps in making a tester for these cables that you will use in conjunction with your multimeter to quickly verify the proper assembly of 10Base-T cables.

On With the Show

If you have gotten this far - if I haven't lost you yet - you are probably ready to make your cable tester. This tester is a very simple two-piece unit that allows one person to check the operation of 10Base-T cables with a minimum of fuss. One unit is a loopback unit, while the other is a breakout unit to which the multimeter is connected. It's really pretty simple. One end of the assembled cable is plugged into each of the tester units. The total cost of the tester unit (less the multimeter as discussed earlier) is under $15.00! If you have some scrap bell wire around, your cost will be right around $10.00.

Here's what you will need:

Materials:
hookup wire, 22 ga. solid, 2 ¾ inches long, insulated
hookup wire, 22 ga. solid, 1 ¾ inch long, insulated
modular jack, 8-pin surface mount, Radio Shack p/n 279-411 or equivalent (2 pcs.)

Tools:
wire cutter/stripper
screwdrivers
needle-nose pliers, small
small finishing nail or wire brad
drill motor
twist drill 5/64"
permanent marking pen


Procedure
Refer to the accompanying illustrations while performing the following steps.

1.Using the wire stripper, remove about one-half inch of insulation from each end of the longer piece of 22-gauge hookup wire.

2.Using the wire stripper, remove all of the insulation from the shorter piece of 22-gauge hookup wire.

3.Remove the covers from both of the modular jacks, and then set one jack and its cover aside for use in Step #15 below.

4.Loosen (but do not remove) screws #1, 2, 3, & 6 on the jack terminal block.

5.Using the needle-nose pliers, bend the short piece of hookup wire into an "S" shape.


6.Place the bent piece of hookup wire under the heads of screws #1 & 2 as shown, being careful not to dislodge the jack connector leads already under the screw heads.


1.


2.Tighten screws #1 & 2 securely.
3.Using the needle-nose pliers, place opposite bends in the ends of the long piece of hookup wire, so that the wire forms an elongated "S" shape.


4.Place the bent piece of hookup wire under the heads of screws #3 & 6 as shown, being careful not to dislodge the jack connector leads already under the screw heads.

5.Tighten screws #3 & 6 securely.
6.Examine your work carefully, making certain that none of the jack connector leads are in contact with each other, nor with the newly-added wires.
7.Replace the cover on this jack terminal block.
8.Using a permanent marker, label the assembled jack with the legend LOOPBACK.
9.Locate the jack terminal block set aside in Step #4 and remove screws #1, 2, 3, & 6.

10.Locate the cover for this jack terminal block and install it onto the block.
11.Turn the assembled jack upside-down on the bench.
12.Using the finishing nail, and inserting it through each open screw hole in turn, mark the cover in line with the screw locations by tapping on the head of the nail. These marks will become drill centers for Step #20.

13.Remove the cover from the jack terminal block.
14.Using the drill motor and the 5/64" twist drill, carefully drill through the cover in each of the four locations marked.
15.Reinstall the four screws removed in Step #15, being careful to secure each of the jack connector leads under its correct screw head. Tighten the screws securely.
16.Replace the cover on this jack terminal block.
17.Using the permanent marker, label each of the four holes in the cover with the numbers 1, 2, 3, & 6 as shown.
18.Draw connecting lines on the cover between holes #1 & 2, and between holes #3 & 6.
19.Label the assembled jack with the legend BREAKOUT.
20.The assembly steps are now completed!


Using the Tester

Using the tester is simplicity itself, and all testing can be done with the suspect cables in place. There is no need to remove any so-installed cables from conduits for testing. Start out by inserting one end of the suspect cable into the jack in the loopback unit. Then go to the other end of the cable and insert it into the jack in the breakout unit. Now, working at the breakout unit, set your multimeter for continuity testing. Next, insert one lead of the meter into hole #1 and the other into hole #2, being sure to insert the test leads until they come into contact with the screw heads in the terminal block. The meter should indicate continuity between these two points. Repeat the process using holes #3 and #6. Again, the meter should indicate continuity. If both of these test show continuity to exist, the cable is intact and should be usable. Any lack of continuity in the above tests indicates a faulty cable. Testing procedures are the same for straight-through and crossover cables.

Occasionally, you may wish to determine whether a particular cable is a straight-through cable or a crossover cable. This can usually be done through careful examination of the wire sequences in the RJ-45 connectors at the opposite ends of the cable. Sometimes though, the cable will have opaque connectors or connector boots, making it difficult to see the wire colors within. This determination is very easily made using two breakout units. Note that this particular procedure does require removal of installed cables, as you must access both ends at once with your multimeter. It also requires that you prepare a second breakout unit as described in Steps 15 through 25 above. Simply connect one breakout unit to each end of the cable and check for continuity between both holes #1 of each breakout unit. If there is continuity from hole #1 to hole #1 of the opposite unit, the cable is a straight-through cable. If there is no continuity shown in that test, check between hole #1 of one unit and hole #3 of the other. Continuity there indicates that the cable is a crossover cable.

(source : http://www.pcnineoneone.com)